Formulation referenceHow to estimate concentrate dilution by mass
For an initial water-only bench calculation, a soluble-solids balance can estimate how much concentrate and water are needed to reach a selected target Brix. In juice, refractometer Brix is an estimate of soluble solids on a sucrose-equivalent scale; it is not a direct measurement of every individual sugar.
Calculation assumptions: concentrate plus water only, negligible solids in the water, no processing loss, and source and target Brix expressed on a compatible analytical basis. Treat the result as a starting estimate and verify the mixed sample. Added sugars, acids, other ingredients and evaporation require a fuller formulation balance.
Starting with a known concentrate quantity
Final mass = Concentrate mass × (Concentrate Brix ÷ Target Brix)
Water to add = Final mass − Concentrate mass
Worked example: 100 kg at 65 °Bx to a 12 °Bx trial target
This is an illustrative formulation target, not a single-strength standard or a PFVN product specification.
The total dilution factor is approximately 5.42: one part concentrate becomes 5.42 parts finished mixture. That is different from adding 5.42 parts water. Always identify whether a ratio refers to added water or total mixture.
Starting with a planned final batch size
Concentrate mass = Final batch mass × (Target Brix ÷ Concentrate Brix)
Water mass = Final batch mass − Concentrate mass
For a 1,000 kg trial batch at 12 °Bx using 65 °Bx concentrate, the estimate is 184.62 kg concentrate plus 815.38 kg water.
Verify the bench trial before scaling up
- Use the actual lot Brix and the supplier's analytical basis, rather than relying only on a nominal product description.
- Weigh the ingredients, mix thoroughly and obtain a representative sample using your established sampling procedure.
- Measure Brix with a calibrated instrument using the specified temperature conditions and any required corrections.
- Check acidity, pH, sensory performance and application-specific requirements; document any adjustments.
- Confirm the final formula and process with your technical team before production.
Mass is not volume. Do not substitute liters or gallons directly into these equations. Volume-based batching requires appropriate density information at the relevant temperature.